Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Online Status
N/A
MBT
N/A
Query only.
Returns the online status of the unit (useful in redundant configurations) in
the form x.
Return position of corresponding RF switch.
Example for MBT-4000B base unit:
<0001/ONL?{cr}
>0001/ONL={cr}{lf}
ON1=ON ,{cr}
ON2=ON , {cr}{lf}
Example for BDC:
<0001A1/ONL?{cr}
>0001A1/ONL=1{cr}{lf}
Example for BUC:
<0001A2/ONL?{cr}
>0001A2/ONL=1{cr}{lf}
ONL=
ONL?
ONL?
ONL=x
Retrieve
AUX
COMM I/O
N/A
MBT
1 byte, numeric
Query only.
Used to Retrieve AUX COMM I/O of the MBT-4000B base unit, in the form
n, where:
n=1 (AUX COMM)
Example: <0001/RAI?1
Returns:
>0001/RAI=
12V1=On
IO1A=0
IO1B=1
RSVD=0
Note: 0=Logic low or input voltage < 0.5 vdc.
1=Logic level 1 or input voltage > 2.7 vdc.
RAI=
RAI?
RAI*
RAI?n
RAI=x
(see Description of
Arguments for
details)
Redundancy
Mode
RAM=um
MBT
2 bytes, numeric
Command or Query.
Sets or returns redundancy mode in the form um, where:
u=1 (Unit 1) or 2 (Unit 2)
m=0 (Manual Mode) or 1 (Automatic Mode)
Example: RAM=11
RAM=
RAM?)
RAM*
RAM?u
RAM=um
(same format as
command
arguments)