Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–18
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Configuration
Status
N/A
All
65 bytes (MBT),
98 bytes (BDC),
76 bytes (BUC),
alphanumeric
Query only.
Returns the configuration status of the unit
Example for MBT-4000B base:
<0001/RCS?{cr}
>0001/RCS={cr}
BF1=X {cr}
BF2=X {cr}
BT1=DN{cr}
BT2=UP{cr}
RED=0{cr}
RAM=00{cr}
MBT=N, A, or B
EXT=0{cr}{lf}
Example for BUC/BDC:
<0001A1/RCS?{cr}
>0001A1/RCS={cr}
FLO=06300{cr}
ATT=01.00{cr}
MUT=1{cr}
SLP=0.3{cr}
LCS=0{cr}
LCW=99{cr}
LFL=1{cr}
REF=XXXX{cr} (reserved for future use)
XRE=X{cr} (reserved for future use)
AFR=0{cr}{lf}
Note: For BUC LCS, LCW, & LFL will not be shown.
N/A
RCS?
RCS=x….x
(see Description of
Arguments for
details)
Redundancy
State
RED=x
MBT
1 byte
Command or Query.
Controls redundancy state in the form x, where:
x=0 (Off),
1 (Enables redundancy using single base unit), or
2 (Enables redundancy using dual base units)
Example: RED=1
RED=
RED?
RED*
RED?
RED=x
(same format as
command
arguments)