Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–21
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Serial Number
N/A
All
9 bytes, numeric
Query only.
Returns the unit’s 9 digit serial number. Slave returns its S/N, in the form
xxxxxxxxx.
Example: RSN=000000165
N/A
RSN?
RSN= x….x
(see Description of
Arguments for
details)
Retrieve
Utility Status
N/A
MBT
24 bytes,
alphanumeric
Query only.
Returns the utility status of the MBT-4000B base unit..
Example:
<0001/RUS={cr}
>0001/RUS={cr}{lf}
ADR=0001{cr}
BDR=9600{cr}{lf}
N/A
RUS?
RUS=x….x
(see Description of
Arguments for
details)
Remote Baud
Rate
SBR=xxxx
MBT
4 bytes,
Command or Query.
Sets or returns the remote baud rate as follows: in the form xxxx, where:
9600=9600 baud
19K2=19200 baud
SBR=
SBR?
SBR!
SBR?
SBR=xxxx
(same format as
command
arguments)
Summary Fault
Status
N/A
All
N/A
Query only.
Returns the status of the Summary Fault Relay in the form x, where:
x=0 (OK) or 1 (FLT)
Example: SFS?
N/A
SFS?
SFS=x
(see Description of
Arguments for
details)
Remote Address
SPA=xxxx
MBT
4 byte, numeric
Command or Query.
Sets or returns the Physical Address of the MBT-4000B base unit in the
form xxxx, where:
xxxx=an address from 0001 to 9999, resolution=0001
Example: SPA=0412
SPA=
SPA?
SPA!
SPA?
SPA=xxxx
(same format as
command
arguments)
Slope Adjust
SSA=x.x
BDC
BUC
3 bytes, numeric
Command or Query.
Sets or returns the Slope adjust level in the form x.x, where:
x.x=valid number from 0.0 to 1.0, resolution=0.1
Example: SSA=0.3
SSA=
SSA?
SSA*
SSA!
SSA?
SSA=x.x
(same format as
command
arguments)
Set Redundancy
Switch
SSW=xy
MBT
2 bytes,
alphanumeric
Command only.
Sets the switches dedicated to Slot 1 or 2, and sets them to either Port A
or Port B in the form xy, where:
x =1 (Slot 1) or 2 (Slot 2)
y=A (Switched to Converter on MBT_A) or B (Switched to Converter on
MBT_B)
SSW=
SSW=xy
N/A
SSW=xy
(same format as
command
arguments)