Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–22
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Set RTC Time
TIM=hhmmss
All
6 bytes, numeric
Command or Query.
Sets or returns the time, indicating the time from midnight, in the form
hhmmss where:
hh=hours, between 00 and 23
mm=minutes, between 00 and 59
ss=seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds
from midnight.
TIM=
TIM?
TIM *
TIM?
TIM=hhmmss
(same format as
command
arguments)
Retrieve Number
of unread
Stored Alarms
N/A
All
2 bytes, numeric
Query only.
Returns the number of Stored Events that remain unread, in the form xx.
Example reply: TNA=18
N/A
TNA?
TNA=xx
(see Description of
Arguments for
details)
Terminal Status
Change
N/A
All
1 byte, numeric
Query only.
Returns the status of the Terminal Status in the form x, where:
x=0 (no change in status) or 1 (change in status)
Example: TSC=0
N/A
TSC?
TSC=x
(see Description of
Arguments for
details)
External
Reference Fault
Logic
XRF=x
MBT
1 byte, numeric
Command or Query.
Sets or returns enabling/disabling the software monitoring of the external
reference source in the form x, where:
x=0 (Ext Reference not monitored) or 1 (Ext Reference is monitored and
the lock state reported)
Note: If enabled and no source is present, a fault will be reported.
Example: XRF=1
XRF=
XRF?
XRF?
XRF=x
(see Description of
Arguments for
details)