Product specifications

Multi-Band Transceiver System Revision 0
Remote Command MN/MBT4000B.IOM
A-17
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes
between 48 and 57)
Response to
Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
LNA/LNB Current
Window
LCW=sxx MBT
BDC
s=1 byte,
value of 1, 2
1=LNA A
2=LNA B
xx=2 bytes,
numeric
Command or Query.
This command allows the user to set the alarm window in ±
% of the calibrated LNA/LNB bias Current. Valid inputs are
20 to 50 in increments of 1%. In addition, setting the value
to 99 disables the alarm function.
Default is disabled.
Example: LCW=230, set alarm window for the LNB bias tee
to ± 30%.
LCW= (message ok)
LCW? (received ok, but
invalid arguments
found)
LCW* (message ok, but
not permitted in current
mode)
LCW! (command not
accepted by BUC or
BDC sub-units)
LCW?s LCW=sxx
(same format
as command
arguments)
LNA/LNB Fault
Logic
LFL=sx MBT
BDC
s=1 byte,
value of 1, 2
1=LNA A
2=LNB bias tee
x=1 byte,
Value of 0, 1
0 = Disable
1 = Enable
Command or Query.
Allows LNA/LNB Fault Logic to contribute to the summary
fault relay as follows:
Source Enable
1=LNA A (Aux Comm 1) 0 = Disabled
2=LNB bias tee 1 = Enabled
Example: LFL=21 would generate a fault if the measured
current for the bias tee varied from the calibrated operating
point stored by the CLC=2 command more the % allowed
by the LCW=2xx command
LFL= (message ok)
LFL? (received ok, but
invalid arguments
found)
LCS* (message ok, but
not permitted in current
mode)
LFL! (command not
accepted by BUC or
BDC sub-units)
LFL?s
s=1 byte,
Value of 1, 2
LFL=sx
(same format
as command
arguments)