Product specifications

Multi-Band Transceiver System Revision 0
Remote Command MN/MBT4000B.IOM
A-27
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes
between 48 and 57)
Response to
Command
(target to controller)
Query
(Instruction
Code and
qualifier)
Response to
query
(target to
controller)
Slope Adjust SSA=x.x BDC
BUC
3 bytes,
numeric
Command or Query.
Slope adjust level, valid from 0.0 to 1.0 with 0.1 resolution.
Example: SSA=0.3
SSA= (message ok)
SSA? (received ok, but
invalid arguments
found)
SSA* (message ok, but
not permitted in current
mode)
SSA! (command not
accepted by MBT-
4000B base unit. It
must be addressed to
BUC or BDC sub-units)
SSA?
SSA=x.x
(same format
as command
arguments)
Set Redundancy
Switch
SSW=xy MBT 2 bytes
Command only.
SSW control the switches dedicated to Slot1 or 2, and sets
them to either Port A or Port B.
Syntax:
SSW=xy
Where:
X = 1 or 2 depicting Slot 1 or 2
Y = A or B depicting the switch direction.
Direction
A Switched to Converter on MBT_A
B Switched to Converter on MBT_B
SSW=(message ok)
SSW=xy
N/A N/A
Set RTC Time TIM=hhmmss All 6 bytes,
numeric
Command or Query.
A command in the form hhmmss, indicating the time from
midnight,
Where:
hh = hours, between 00 and 23
mm = minutes, between 00 and 59
ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and
59 seconds from midnight.
TIM = (message ok)
TIM? (received ok, but
invalid arguments
found)
TIM * (message ok, but
not permitted in current
mode)
TIM?
TIM=hhmmss
(same format
as command
arguments)