Product specifications

UT-4500-A Series Upconverters Revision 0
Appendix A MN-UT4500A
A–20
of the following commands are received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or
PACRAS.
Command Details
Configuration Status: <DEV/TSC_'cr’
Confirmation: >DEV/TSC_nnn'cr''lf'] nnn=YES/NO
A.7.4.7 Packed Configuration Status
Configuration Status: <DEV/PACRCS_'cr'
Confirmation: >DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf']
where:
aaaa = # of 125kHz steps above base frequency
1
bbb = # of 0.25 dB steps above 0.00 dB
2
c = 1 if Transmitter ON, 0 if OFF, 2 if Cold
d = 1 if unit ONLINE, 0 if OFFLINE
e = 1 if Redundancy ON, else 0
ff = converter # (01-12,BU or 00 if e = 0)
gg = 00 if 'ff' is 00 (redundancy OFF)
gg = chain length (01-12) if 'ff' is BU
gg = XX if 'ff' = 01 - 12
h = A if Auto Mode, M if Manual
3
I = 1 if Cold Start Enabled, else 0
j = 1 if Auto recovery enabled, else 0
k = 1 if an Ext. Ref is present, else 0
l = 1 if Remote Mode, 0 if Local Mode
Notes:
1. If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the base
frequency
2. If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above the
base frequency
3. If it is a backup converter, it is always ‘A’
A.7.4.8 Packed Maintenance Status
Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation: >DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']
where:
aa = V15 scaled 123mV per count (0x00 - 0xFF)
bb = V14 scaled 123mV per count (0x00 - 0xFF)
bc = VCC scaled 39mV per count (0x00 - 0xFF)
dd = V5D scaled 39mV per count (0x00 - 0xFF)
eee = signed Temperature in degrees C (-10 to +60)
ff = IFLO tune scaled 67mV per count (0x00 - 0xFF)
gg = SUM tune scaled 54mV per count (0x00 - 0xFF)
hh = COARSE tune scaled 78mV per count(0x00 - 0xFF)
ii = FINE tune scaled 89mV per count (0x00 - 0xFF)