Product specifications

UT-4500-A Series Upconverters Revision 0
Front Panel Operation MN-UT4500A
5–9
5.3.1.3 CONFIG: REDUNDANCY
1:1 Redundancy is an optional feature for the UT-4500-A. If the user attempts to select any feature
from this menu branch, and either Redundancy Configuration is off or the upconverter is the
primary operating unit, the Redundancy menu branch appears as follows:
Redundancy: MODE
Otherwise:
Redundancy: MODE
Auto/Manual FORCE HSB
Use the
! " arrow keys to select MODE, Auto/Manual, FORCE, or HSB (High Speed Bus),
and then press ENTER.
Note: If any submenu is selected from this menu branch when the unit is not in Local Mode (i.e.,
the unit is in either Serial or Ethernet Remote Mode), the system prompts the user to switch or
Local Mode as follows:
Remote Mode: press ENTER
for local mode, or CLEAR
Operations may continue once Local Mode is established.
CONFIG: REDUNDANCY ! MODE
Redundancy Config = On
CONVERTER = #BU 1:01
On the top line: First, use the
! " arrow keys to navigate to the Redundancy Config
setting, and then use the # $ arrow keys to set operation as On or Off.
On the bottom line: First, use the
! " arrow keys to navigate to the Converter Selection
setting, and then use the # $ arrow keys to toggle the upconverter operational preference as
#BU or #01. Note the following:
! With CONVERTER = #BU, the unit is set as the standby, or backup unit. This mode
of operation is indicated on the right-hand side of the bottom line as 1:01.
! With CONVERTER = #01, the unit is set as the primary operating unit. The mode
of operation is indicated on the right-hand side of the bottom line as POL=1.