Product specifications

UT-4500-A Series Upconverters Revision 0
Front Panel Operation MN-UT4500A
5–15
Use the ! " arrow keys to select No or Yes to clear a previously saved parameter from
memory. This will free up the slot for future pre-select programming needs. Press ENTER when
done.
5.3.5 UTILITY
TIME DISP FIRMWARE AID
REFOSC SLOPE LAMP-TEST
Use the
! " arrow keys to select from the submenu choices shown, and then press ENTER. Note
the following:
Submenu Sect Functional Description
TIME 5.3.5.1
Allows configuration of the Real-Time Clock.
DISP 5.3.5.2
(Display) Allows adjustment of the Video Fluorescent Display (VFD) brightness
level.
AID 5.2.5.3
Allows definition of a unit identifier (label).
REFOSC 5.3.5.4
(External Reference Oscillator) Allows adjustment of the upconverter reference
frequency.
SLOPE 5.3.5.5
Allows adjustment of the upconverter slope settings.
LAMP-TEST 5.3.5.6
Performs a diagnostic test of the front panel LEDs and VFD.
5.3.5.1 UTILITY: TIME (Real-Time Clock)
Edit Real-Time Clock:
12:00:00 01/23/11
To edit the time and date settings of the real-time clock, first use the ! " arrow keys to select
the digit to be edited, and then use the # $ arrow keys to change the value of that digit. Press
ENTER when done.
Note: 24-hour Military time format is used.