Product specifications

UT-4500-A Series Upconverters Revision 0
Appendix A MN-UT4500A
A–11
A.7.1.15 Converter Slope Adjustment
The default slope adjustment value is 0.3.
Command Details
Set Slope Adjust: <DEV/SSA_xxx'cr' xxx = 0.0 to 1.0
Confirmation: >DEV/SSA_xxx'cr''lf']
Retrieve Slope Adjust: <DEV/SSA_'cr'
Confirmation: >DEV/SSA_xxx'cr''lf']
A.7.1.16 Equipment Type
Equipment type is a query that retrieves the model number and the software revision of the unit.
This data is read-only.
Command Details
Retrieve Equipment Type: <DEV/RET_'cr'
Confirmation: >DEV/RET_xxxxxxxxxx yyyyyyy'cr’’lf']
xxxxxxxxxx = Model Number
yyyyyyy = Software Version.
A.7.1.17 Part Number
The PNM command retrieves the unit’s part number information. This data is read-only.
Command Details
Retrieve Part Number: <DEV/PNM_'cr'
Confirmation: >DEV/PNM_xx…xx'cr’’lf']
Where:
xx…xx = up to 96 bytes of part number information
A.7.1.18 Legacy Firmware Information
This legacy firmware command no longer provides information about the unit’s firmware type. It
is included only to provide backwards compatibility with existing monitor and control software
applications. To query the unit’s firmware information refer to the FRM command.
Command Details
Retrieve Firmware Information: <DEV/FRW_’cr’
Confirmation: >DEV/FRW_’cr’
BULK= FWnnnn-nr Ver=x.xx’cr’
M&C = FWnnnn-nr Ver=x.xx’cr’
FPGA= FWnnnn-nr Ver=x.xx’cr’’lf’]
Where: nnnn-n firmware number
r firmware revision
x.xx firmware version
Note: BULK, M&C, and FPGA have different firmware numbers,
revisions, and versions among each other.