Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Introduction Revision 2
13
Characteristic Specification
Phase Noise
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
LIMIT
TYPICAL
-66 dBc/Hz -69 dBc/Hz
-76 dBc/Hz -79 dBc/Hz
-86 dBc/Hz -89 dBc/Hz
-96 dBc/Hz -99 dBc/Hz
-106 dBc/Hz -109 dBc/Hz
Indicators
Power On
Mute
Remote
Reference
Stored Fault
Fault
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Test Points
RF Sample
IF Sample
SMA, -20 dBc Nominal
BNC, -20 dBc Nominal
Power
Voltage
Frequency
Dissipation
90-250 Vac Autoranging
47-63 Hz
60 Watts
Environment
Temperature
Altitude
Humidity
0 - 50° C (32 to 122° F)
10,000 Feet MSL
0-95 % Relative
Physical
Width
Height
Depth
Weight
19 Inches (48.30 cm)
1.75 Inches (4.45 cm)
22 Inches (55.90 cm)
15 Pounds (7.00 kg)
Options
- 1
- 2
IO Module
RF/IF Switch
Summary Alarm
Relay Closure
Form C