5.6.2.2 ATTENUATOR
The default is 10 dB.
Command Details
Set Attenuator: <DEV/ATT_ yy.yy'cr'
Confirmation: >DEV/ATT_yy.yy'cr'lf']
Retrieve Attenuator: <DEV/ATT_'cr'
Confirmation: >DEV/ATT_ yy.yy'cr''lf']
Note: yy.yy = 0.0 to 25.00 dB in 0.25 steps.
5.6.2.3 COLD START
The cold start function, if enabled, mutes the output signal for a predetermined time
following Power-Up to ensure a stable reference oscillator (15 minutes). The default is
OFF. This command is disabled in redundant systems (i.e. COMMAND NOT
AVAILABLE).
Command Details
Set Cold Start: <DEV/CLD_xxx'cr' xxx = ON or OFF
Confirmation: >DEV/CLD_xxx'cr''lf']
Retrieve Status: <DEV/CLD_'cr'
Confirmation: >DEV/CLD_xxx'cr''lf']
5.6.2.4 MUTE
The default is ON.
Command Details
Mute Output: <DEV/MUT_xxx'cr' xxx = ON or OFF
Confirmation: >DEV/MUT_xxx'cr''lf']
Retrieve Mute
Status:
<DEV/MUT_'cr'
Confirmation: >DEV/MUT_yyy'cr''lf']
yyy = ON/OFF/COLD