Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
70
Command Details
Initialize Command: <DEV/ICT_xx_yy'cr'
Confirmation: >DEV/ICT_xx_yy'cr''lf']
Initialize Status: <DEV/ICT_'cr'
Confirmation: >DEV/ICT_xx_yy'cr''lf']
xx = chain position = 01 to 12, or BU. Where BUselects the
converter as the backup.
yy = chain length for xx = BU (i.e. Backup converter) 01 to 12.
yy = unused if xx = 01 to 12 (i.e. chain converter)
Example 1: The following command assigns the converter chain position "1".
<DEV/ICT_01'cr'
>DEV/ICT_01'cr''lf']
Example 2: The following command assigns the receiving converter as the backup
converter in a 1:8 system.
<DEV/ICT_BU_08'cr'
>DEV/ICT_BU_08'cr''lf']
It should be reiterated that only the converter physically located at the top of a redundant
rack should be assigned as the Backup unit. Likewise, assignment of chain positions in a
redundant rack should be made according to the physical allocation of each converter in
the rack (i.e. The top converter should be the Backup, the second converter should be
assigned chain position 1, the third converter position 2, etc.).
5.6.3.2 AUTOMATIC/MANUAL MODE
This command provides for automatic switching by the backup converter if both units are
in the Redundancy Mode. This command is only accepted by the backup converter. If a
chain converter is set in Manual Mode, the backup converter will log the occurrence and
not act upon further information from the converter until put into Automatic Mode. The
default is off.
Command Details
Automatic Mode: <DEV/SAM_xx_y'cr'
Confirmation: >DEV/SAM_xx_y'cr''lf']
Automatic Status: <DEV/SAM_xx_'cr'
Confirmation: >DEV/SAM_xx_y'cr''lf']
Where: xx = 01 to 12, converter number
y = A for Auto; M for Manual