Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
71
5.6.3.3 BACKUP MODE
This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
converter (i.e., “BU”). When activated this command forces the backup converter to
assume the state of the specified chain converter and forces the chain converter offline.
Command Details
Initiate a Backup: <DEV/FBU_xx_y'cr'
Confirmation: >DEV/FBU_xx_y'cr''lf']
Where: xx = 01 to 12, converter number
y = ‘F’ to force a backup ‘N’ to remove a backup
Retrieve Backup
Status:
<DEV/FBU_'cr'
Confirmation: >DEV/FBU_xx_zzzzz'cr''lf']
Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter
number is not displayed.
zzzzz = ‘NONE’ if no backup active
= ‘ACTIVE’ if an automatic backup has occurred
= ‘FORCED’ if a forced backup is active
5.6.4 STATUS COMMANDS
Status commands retrieve configuration, maintenance and alarm status in summary form.
5.6.4.1 CONFIGURATION STATUS
Command Details
Configuration Status: <DEV/RCS_'cr'
Confirmation: >DEV/RCS_'cr'
FRE_xxxxx.xxx'cr' Frequency
ATT_yy.yy'cr' Attenuator
TX_nnn'cr' Transmitter - ON/OFF/COLD
ONL_nnn'cr' Online - ON/OFF
RED_xx_yy_z'cr' See Note
CLD_nnn'cr' Cold Start - ON/OFF
AFR_nnn'cr' Auto Flt Recovery-ON/OFF
EXT_xxx'cr''lf'] Ext. Ref. - YES/NO
Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as
backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain
(i.e. 01 to 12), else if Redundancy ON and converter selected as a chain unit xx is the
converter number (01 to 12), and z = A if Auto Mode or M if Manual Mode.