Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
72
5.6.4.2 MAINTENANCE STATUS
Command Details
Maintenance Status: <DEV/RMS_'cr'
Confirmation: >DEV/RMS_'cr'
P15_xx.x'cr' 15 Vdc Supply
P14_xx.x'cr' 14 Vdc Supply
VCC_x.x'cr' VCC Supply
5VD_x.x'cr' Display 5 Vdc
TEM_xx'cr' Temperature
IFL_xx.x'cr' IFLO Tuning
SUM_xx.x'cr' Sum Loop Tuning
COR_xx.x'cr' Coarse Loop Tune
FIN_xx.x'cr''lf'] Fine Loop Tuning.
5.6.4.3 UTILITY STATUS
Command Details
Utility Status: <DEV/RUS_'cr'
Confirmation: >DEV/RUS_'cr'
COMM_aaaaaa'cr' RS-232 or RS-485
ADD_xxx'cr' Address (001 to 255)
BR_nnnn'cr' Baud Rate (1200, 2400, 4800, 9600,
19K2, or 38K4)
FMT_x-y-z’cr’ Data Format x=data, y=parity, z=stop
bit (8-N-1, 7-E-2, 7-O-2)
REF_xxx'cr' Osc. Adjust (000 to 255)
SLP_x.x'cr' Slope Adjust (0.0 to 1.0)
CON_xx'cr' LCD Contrast (0 to 30)
LCD_xx'cr''lf'] LCD Brightness (0 to 30).
5.6.4.4 ALARM STATUS
Command Details
Alarm Status: <DEV/RAS_'cr'
Confirmation: >DEV/RAS_'cr'
P15_xx'cr' 15 Vdc Fault
P14_xx'cr' 14 Vdc Fault
VCC_xx'cr' VCC Fault
5VD_xx'cr' 5VD Fault
TEM_xx'cr' Temperature Fault
IFL_xx'cr' IFLO Lock Fault
SUM_xx'cr' Sum Lock Fault
COR_xx'cr' Coarse Lock Fault
FIN_xx'cr' Fine lock Fault
HSB_xx’cr’ High Speed Bus Fault
*REF_xx'cr''lf'] Ref. Lock Fault
xx = OK or FT
Note: REF_xx is only returned if an external reference is present.