Product specifications

UT4500 Series Up Converter MN/UT4500.IOM
Remote Control Revision 2
78
5.8 CONVERTER REMOTE COMMAND SUMMARY
Table 14. Remote Command Summary
Utility Commands Paragraph
Set Time <DEV/TIM_hh:mm:ss'cr' 5.6.1.1
Set Date <DEV/DAT_mm/dd/yy'cr' 5.6.1.2
Set Physical Address <DEV/SPA_xxx'cr' 5.6.1.3
Set Baud Rate <DEV/SBR_xxxx'cr' 5.6.1.4
Set LCD Contrast <DEV/CON_xx'cr' 5.6.1.5
Set LCD Brightness <DEV/LCD_xx'cr' 5.6.1.6
Set Reference Oscillator
<DEV/SRO_xxx'cr'
5.6.1.7
Set Converter Slope Adj. <DEV/SSA_xxx'cr' 5.6.1.8
Retrieve Equipment Type <DEV/RET_'cr' 5.6.1.9
Retrieve Firmware Information <DEV/FRW_'cr' 5.6.1.10
Set Application ID Message <DEV/AID_xxxxx...xxxxx'cr' 5.6.1.11
Configuration Commands Paragraph
Set Frequency <DEV/FRE_xxxxx.xxx'cr' 5.6.2.1
Set Attenuation <DEV/ATT_xx.xx'cr' 5.6.2.2
Select Cold Start Mode <DEV/CLD_xxx'cr' 5.6.2.3
Mute/Unmute Converter <DEV/MUT_xxx'cr' 5.6.2.4
Select Auto Fault Recovery Mode <DEV/AFR_xxx'cr' 5.6.2.5
Program a Preset <DEV/PGM_nn_xxxxx.xxx_yy.yy'cr' 5.6.2.6
Display All Presets <DEV/DPS_'cr' 5.6.2.7
Clear a Preset <DEV/CLR_nn'cr' 5.6.2.8
Select a Preset <DEV/SEL_nn'cr' 5.6.2.9
Redundancy Mode Commands Paragraph
Select Redundancy ON/OFF <DEV/RED_xxx’cr’ 5.6.3.1
Configure Redundant Converter <DEV/ICT_xx_yy’cr’ 5.6.3.1
Select Auto/Manual Mode <DEV/SAM_xx_y'cr' 5.6.3.2
Forced Backup Mode <DEV/FBU_xx_y'cr' 5.6.3.3