Instruction Manual

32 - Device Driver Installation DeviceMaster 500 User Guide: 2000501 Rev. A
Device Driver Installation
7. Set WCOM2 to view Hex data by selecting the View/Hex Display menu option.
Hex Display displays a check when selected.
Note: All the communications with the scanner are in Hex format.
8. Connect the power cord of the scanner to a power source. When the scanner
displays a green light, you should see a message on the WCom2 window.
9. Use the Port/Send ASCII / HEX String menu to send the appropriate hex
commands using LMS scanner manual to perform these steps:
a. Send a request to the scanner to start measuring.
b. Send a request to the scanner to stop measuring.
c. Send a request to the scanner to set the baud rate to 500K.
d. After you get the
confirmation, change the
COM port setting in
WCOM2 to 500K by using
the Settings/Port Settings
menu.
e. Repeat Steps a
and b to
make sure that the
scanner is working at
500K.
Note: You can use this step for
any baud rate.