MODEL W150 W200 W300 W400
Performance characteristics (with full hopper)
Air flow {SCFM}
*
75 100 150 200
Air flow {ACFM @ 250
°F
}
*
101 134 201 268
Drying temperature All models 100 - 375
°
F {38 - 191
°
C} with options
dewpoint All models -40
°
F {-40
°
C}
Dimensions inches {cm}
A - Height 70.4 {178.8}
B - Overall width 29 {73.7}
C - Control width 24 {61.0}
D - Depth 51.5 {130.8}
Control depth 8 {20.3}
Outlet/inlet tube size OD 2.5 5 5 5
Weight lbs {kg}
Standard Dryer Installed 600 {272} 660 {300} 710 {322} 760 {345}
Voltage - Total Amps
230 V/3 phase/60 Hz 47.1 61.4 67 N/A
400 V/3 phase/50 Hz 25.8 34 38.5 63.6
460 V/3 phase/60 Hz 23.6 30.7 33.5 55.3
575 V/3 phase/60 Hz 18.9 24.7 26.8 44.3
Total kilowatts kW {BTU/min} 6.2 {353} 8 {455} 11 {625} 14 {800}
Water requirements {for optional aftercooler or precooler}
Recommended temperature* 45
°
- 85
°
F
Water flow gal./min. {liters/min.} 3 {11.4}
Water connections NPT 3/4 in. NPT
SPECIFICATION NOTES:
* The term SCFM stands for Standard Cubic Feet Per Minute, referenced to a pre-specified pressure, temperature
and relative humidity. In most cases, SCFM is referenced to 14.7 PSIA 68° F and 36% relative humidity. ACFM
stands for Actual Cubic Feet Per Minute, and must be supplied with a temperature reference, due to the change
in air density with temperature. Because dryers operate at a relatively low pressure the effects on air density are
negligible.
Dryers running at 50 HZ will have 17% less airflow, and a 17% reduction in material throughput.
Specifications may change without notice. Consult a Conair representative for the most current information.