User guide
Specifications: Dust Collector DC1 and DC2
Description l 2-3
2
Description
MODELS DC1 DC2
Performance Characteristics
Pump size range
Hp {kW} * 3-7.5 {2.2-5.6} 10-25 {7.5-18.7}
Vacuum line size OD in {mm} 1.5-2.5 {38.1-63.5} 2.25-4.0 {57.2-101.6}
Filter area ft
2
{
M
2
}
42.8 {4.0} 100.3 {9.3}
Maximum collection capacity ft
3
{liters} 1.1 {31.1} 2.1{59.4}
Recommended dust collection ft
3
{liters} 0.75 {21.2} 1.0 {28.3}
Dimensions inches {cm}
A - Height 58.0 {147.3} 67.0 {170.1}
B - Width 15.0 {38.1} 19.0 {48.3}
Depth 20.0 {50.8} 19.0 {48.3}
Weight lb {kg}
Installed 110 {49.9} 150 {68.0}
Shipping 140 {63.5} 280 {127.0}
Voltage total amps
120V/1 phase/60Hz 1.0 1.0
Compressed air requirement
80-120 psi {5.5-8.3 bars}
SPECIFICATION NOTES:
* Model DC1 works with Conair pump models RG-1-3, RG1-6, PD3, PD5, and
PD7.5.
Model DC2 works with RG1-11, RG2-16, PD10, PD15 and PD25.
Specifications can change without notice. Check with a Conair representative
for the most current information.
A
B
in
out
Model DC1 and DC2