Installation l 3-5
Installation (continued)
Compressed Air Connections
Connect a compressed air line (80-100 psi) to the inlet of the solenoid valve which
is located on the mounting plate of the filter chamber. An air line is connected
from the solenoid to the vacuum breaker valve within the filter chamber. If the
automatic unload/reload section is used, a line will also be ran to the solenoid
valve mounted on the outside of the reload control. Compressed air must be fil-
tered free of moisture. Automatic unload/reload units come equipped with com-
pressed air filters.
DO NO
T connect compressed air to the 0.75 in. {19.05 mm} solenoid air vent
located on the bottom section of the automatic unload/reload dust collector.
Electrical Connections
Proper operation of the dust collector depends upon its internal vacuum valve
opening whenever the vacuum pump is energized. Electrical connections are pro-
vided by a 3-conductor cable connected to the dust collector. This cable should be
connected to the vacuum pump control enclosure to provide simultaneous opera-
tion of the dust collector when the pump is activated. On automatic unload/reload
dust collectors, the cable is attached to the reload control enclosure, which distrib-
utes power to the various solenoids for the auto reload function of the dust collec-
tor.
3
Installation
IMPORTANT: Always refer to the wiring diagrams that came with your equipment
to locate specific electrical components. Illustrations and photographs in the User
Guide are intended only to be representative only.