System information

P29
Picture 4.6 set the time section
IntervalOnly one alarm signal is turned on even there are several motion detect signals in the set
interval.
Alarm outputStart the external equipment of corresponding linkage alarm when the motion detect
alarm is turned on.
DelayDelay a few moments and stop when the alarm state is turned off. The range is 10~300
seconds.
Record channelChoose the recording channel (multiple option supportive). Trigger the video
signal when the alarm is turned on.
Note:Set in the [recording setup] and perform the linkage recording. Start detecting video files
in the corresponding time section.
Tourmeans that the selective channel is single window alternate patrol preview. The interval is
set in the [Main Menu]>[System] > [Tour].
PTZ ActivationSet the PTZ activation when the alarm is turned on.
*Hybrid mode, PTZ link to the related PTZ information of analog channel, While digital
channel model, the PTZ is link to the related PTZ information on the remote device connected.
Noteto link PTZ, need go [Shortcut menu]->[PTZ control] to set preset point, cruise between
points & interval time, etc.