CDMA router CR10 v2 USER’S MANUAL LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
USED SYMBOLS Used symbols Danger – important notice, which may have an influence on the user’s safety or the function of the device. Attention – notice on possible problems, which can arise in specific cases. Information, notice – information, which contains useful advice or special interest. GPL license Source codes under GPL license are available free of charge by sending an email to: info@conel.cz. Conel s.r.o.
CONTENTS Contents 1 Safety instruction 1 2 Product disposal instructions 2 3 Router description 3 4 Contents of package 4 5 Router design 5 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 Router versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delivery identification . . . . . . . . . . . . . . . . . . . . . . . . . . Version of firmware module . . . . . . . . . . . . . . . . . . . . . . . Ordering codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.1 Basic version . .
CONTENTS 7.1 7.2 7.3 7.4 7.5 Technical parameters of router . . . . . Technical parameters of module . . . . Technical parameters of processor . . . Technical parameters I/O port . . . . . . Technical parameters of expansion port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF FIGURES List of Figures 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 40 Contents of package . . . . . . . . . . . . . Front panel CR10 v2B . . . . . . . . . . . . Front panel CR10 v2F . . . . . . . . . . . . Front panel CR10 v2B SL . . . . . . . . . . Front panel CR10 v2F SL . . . . . . . . . . Label CR10 v2B . . . . . . . . . . . . . . . Label CR10 v2B SL . . . . . . . . . . . . . Label CR10 v2F . . . . . . . . . . . . . . .
LIST OF TABLES List of Tables 1 2 3 4 5 6 7 8 9 10 11 12 12 13 14 15 Router versions . . . . . . . . . . . . . Delivery identification . . . . . . . . . Version of firmware module . . . . . . Ordering codes of basic version . . . . Ordering codes of full version . . . . . Front panel description . . . . . . . . . Router status indication . . . . . . . . Connection of power connector . . . . Connection of Ethernet connector . . . Connection of USB connector . . . . . Connection of I/O port . . . . . . . .
1. SAFETY INSTRUCTION 1. Safety instruction Please, observe the following instructions: • The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the router in prescribed applications and environments. • To prevent possible injury to health and damage to appliances and to ensure that all the relevant provisions have been complied with, use only the original accessories.
2. PRODUCT DISPOSAL INSTRUCTIONS 2. Product disposal instructions The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled. At the end of it’s life this product MUST NOT be mixed with other commercial waste for disposal.
3. ROUTER DESCRIPTION 3. Router description CDMA wireless router CR10 v2 is used to wirelessly connect various equipments and devices via Ethernet interface 10/100 to the Internet or intranet. Thanks to high data transfer speed of up to 14.7 Mbit/s (download) and upload speed up to 5.4 Mbit/s it is an ideal wireless solution for traffic and security camera systems, individual computers, LAN networks, automatic teller machines (ATM) and other self-service terminals, etc.
4. CONTENTS OF PACKAGE 4. Contents of package Basic delivered set of router includes: • • • • • • • router, power supply, crossover UTP cable, two external antennas, clip for the DIN rail, installation CD containing instructions, paper start guide. Figure 1: Contents of package Note: The router box and DIN mount are supplied in a metal case in the SL version.
5. ROUTER DESIGN 5. Router design 5.1 Router versions CR10 v2 router is supplied in the following versions: Box CR10 v2B Plastic CR10 v2B SL Metal CR10 v2F Plastic CR10 v2F SL Metal SIM1 SIM2 I/O USB PORT1 Table 1: Router versions PORT2 ETH Figure 2: Front panel CR10 v2B Figure 4: Front panel CR10 v2B SL Figure 3: Front panel CR10 v2F Figure 5: Front panel CR10 v2F SL 5 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel.
5. ROUTER DESIGN 5.2 Delivery identification Trade name Type name Other CR10 v2B CR-10-v2 Basic version CR10 v2B SL CR-10-v2 Basic version in the metal box CR10 v2F CR-10-v2 Full version CR10 v2F SL CR-10-v2 Full version in the metal box Table 2: Delivery identification Figure 6: Label CR10 v2B Figure 8: Label CR10 v2F Figure 7: Label CR10 v2B SL Figure 9: Label CR10 v2F SL 6 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
5. ROUTER DESIGN 5.3 Version of firmware module Each operator can have another CDMA network, so it is necessary to generate a special firmware for each operator. Version of the firmware is indicated by two-digit code in the name of the product. Operator Code Poland Orange 01 Poland Plus 02 Czech Republic O2 03 Germany Inet 04 Sweden Net.1 05 Norway Net.1 06 Russia Skylink 07 Table 3: Version of firmware module Example of trade name: Example of type name: CR10 v2B-01 CR-10-v2B ver.
5. ROUTER DESIGN 5.4 Ordering codes Order codes are given for the Polish operator Orange. Another operator can be selected by changing two digits according to Table 3 Version of firmware module on page 7. 5.4.
5. ROUTER DESIGN 5.5 Basic dimensions of plastic box Figure 10: Basic dimensions of plastic box 5.6 Basic dimensions of metal box Figure 11: Basic dimensions of metal box 9 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
5. ROUTER DESIGN 5.7 Mechanical dimensions and mounting recommendations Mounting recommendations: • possibility to be put on a work surface, • DIN rail with clips CKD2 (ELPAC clip SL for metal version) are included. For the most of applications with a built-in router in a switch board it is possible to recognize two kinds of environments: • no public and industry environment of low voltage with high interference, • public environment of low voltage without high interference.
5. ROUTER DESIGN • For every cables we recommend to bind the bunch according to the following picture, we recommend for this use: – Length of the bunch (combination of power supply and data cables) can be maximum 1,5 m. If the length of data cables exceeds 1,5 m or in the event of, the cable leads towards the switch – board. We recommend installing over – voltage protectors (surge suppressors). – With data cables they mustn’t carry cables with reticular tension ∼ 230 V/50 Hz.
5. ROUTER DESIGN 5.8 Removing from the DIN rail Default position of CPD2 holder (or CKD2 holder for SL version), which is used for mounting the router on a DIN rail, is shown in the following figure: Figure 18: Default position of DIN holder For removing from the DIN rail it is necessary to lightly push upward the router so that the top part of the CPD2 holder (or CKD2 for SL version) hitched to the DIN rail get out of this rail and then fold out the top part of the router away from the DIN rail.
5. ROUTER DESIGN 5.9 Description of the front panel On the front panel is located: Caption Connector Description PWR 2-pin Connector for the power supply adapter. ETH RJ45 Connector for connection into the local computer network. PORT1 RJ45 Connector for expansion port RS232, RS458/422, MBUS, ETHERNET, CNT or SWITCH. PORT2 RJ45 Connector for expansion port RS232, RS485/422, MBUS, SWITCH, WIFI, WMBUS or SDH (only FULL version). ANT SMA Connector for main antenna.
5. ROUTER DESIGN 5.9.1 Status indication About router status inform eight led indicators on the front panel and on every port are two LED indicators, which inform about port status.
5. ROUTER DESIGN 5.9.2 Power connector PWR Panel socket 2-pin. Pin number Signal mark Description 1 VCC(+) Positive pole of DC supply voltage (+10 to +30 V DC) 2 GND(-) Negative pole of DC supply voltage Table 8: Connection of power connector Figure 21: Power connector Power supply for router is required between +10 V to +30 V DC supply. Protection against reversed polarity without signaling is built into the router. The power consumption during receiving is 2,3 W.
5. ROUTER DESIGN 5.9.3 Antenna connector ANT, DIV (alternatively WIFI or WMBUS) Main and diversity antennas are connected to the router using the SMA connector on the front panel. If WIFI or WMBUS expansion port is eqquiped on customer’s request, on the front panel is also available the third SMA antenna connector, through which the additional antenna can be connected (it is reverse connector R-SMA in case of the WIFI expansion port).
5. ROUTER DESIGN 5.9.4 SIM card reader The SIM card reader for 3 V and 1,8 V SIM cards is located on the front panel of the router. To initiate the router into operation it is necessary to insert an activated SIM card with unblocked PIN in the reader. The SIM cards might be of different adjusted APN (Access Point Name). Changing the SIM card: Before handling of the SIM card turn off the router and disconnect it from power supply. Press the small yellow button to eject the reader holder.
5. ROUTER DESIGN Figure 27: Ethernet connector ATTENTION! Port ETH is not POE (Power Over Ethernet) compatible! Ethernet cable plug into the RJ45 connector labeled as ETH (see figure below). Figure 28: Connection of ethernet cable Example of the ETH router connection: Figure 29: Example of router connection 18 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
5. ROUTER DESIGN 5.9.6 PORT1 The PORT1 is equipped on customer’s request with one of the offered expansion ports: • RS232 • MBUS • RS485/422 • CNT • ETHERNET • SWITCH (together with PORT2) Description and examples of expansion ports connection can be found in user’s guide for corresponding expansion port. PORT1 cable plug into the RJ45 connector labeled as PORT1 (see figure below). Figure 30: PORT1 cable connection 5.9.
5. ROUTER DESIGN PORT2 cable plug into the RJ45 connector labeled as PORT1 (see figure below). Figure 31: PORT2 cable connection 5.9.8 USB Port Panel socket USB-A.
5. ROUTER DESIGN Example of connecting devices with serial interface to the USB: Figure 33: Connection PLC to the router Example of connecting of USB flash disk to the USB: Figure 34: Connection flash memory to the router 5.9.9 I/O Port Panel socket 3pin. Pin Signal mark Description Data flow direction 1 BIN0 Binary input Input 2 GND Signálová zem 3 OUT0 Binary output Output Table 11: Connection of I/O port Figure 35: I/O connector 21 LUCOM GmbH * Ansbacher Str.
5. ROUTER DESIGN The user interface I/O is for processing of binary input signal and to control (settings) of binary output signal. Binary output is not switched to ground in the default configuration. Maximum load binary output is 30 V / 100 mA. The constant current supplied by the binary input is 3 mA. Connector I/O cable connect into the I/O connector on the router head and tighten locking screws (see figure below).
5. ROUTER DESIGN 5.9.10 Reset It is important to distinguish between reset and reboot the router.
6. FIRST USE 6. First use 6.1 Connecting the router before first use Before you give up the router, it is necessary to connect all components needed for the operation of your applications and the SIM card must be inserted (see figure below). The router can not operate without connected antenna, SIM card and power supply. If the antenna is not connected, router can be demaged. Figure 40: Router connection 24 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax.
6. FIRST USE 6.2 Start The router is set up connecting the power supply to the router. In the default setting the router starts to login automatically to the preset APN. Device on the Ethernet port DHCP server will assign addresses. The behavior of the router can be modified by means of the web or Telnet interface, which is described in the configuration manual. The power consumption during receiving is 2,3 W. The peak power consumption during data sending is 5,5 W.
7. TECHNICAL PARAMETERS 7. Technical parameters 7.1 Technical parameters of router CR10 v2 Complies with standards EN 301 526, v1.1.1, EN 62311:2008 ETSI EN 301 489-25 v2.3.2, EN 60950-1:06 ed.2 + A11:09 + A1:10 + A12:11 + Opr.
7. TECHNICAL PARAMETERS 7.3 Technical parameters of processor 32b ARM mikroprocesor Memory 512 Mb DDR SDRAM 128 Mb FLASH 1 Mb MRAM Interface Serial interface RS232 Ethernet interface 10/100 Mbit/s USB 2.0 interface Table 14: Technical parameters of processor 7.4 Technical parameters I/O port 32b ARM mikroprocesor Input/Output Binary input Binary output Reed contact with trigger level 1,3 up to 1,4 V 100 mA / max. 30 V Table 15: Technical parameters I/O port 7.
8. RECOMMENDED LITERATURE 8.
9. POSSIBLE PROBLEMS 9. Possible problems Some network cards are able to be set in situation, when it is not possible to connect the router. It is possible to solve this problem in the following steps: • hand by selection communication rates 10 MB/s in property network cards, • connect router over switch, • start computer only after finalizing the start of the router. 29 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.
10. FAQ 10. FAQ - I can’t get from internet on equipment, which is connected to router and I have NAT enabled. • The device’s gateway has to be configured as the router. - Router resets itself, connection on Ethernet fails. • It is necessary to use an antenna, which will be situated far from power supply. - I don’t get on web server at NAT.
10. FAQ • The operator doesn’t give out address DNS servers and without DNS server’s it is impossible to connect to server dyndns.org. In log system will be this message: – DynDNS daemon started – Error resolving hostname: no such file or directory – Connect to DynDNS server failed - IPSec tunnel is establishing but communication doesn’t function. • Probably it is badly set up route conditionals of connected equipment or it is bad set up GW. - FTP doesn’t function.
11. CUSTOMERS SUPPORT 11. Customers support You can find current information about this product on our website: www.conel.cz Upkeep-advices: • The SIM-card must be handled carefully as with a credit card. Don’t bend, don’t scratch on this and do not expose to static electricity. • During cleaning of the router do not use aggressive chemicals, solvents and abrasive cleaners! Conel Company hereby declares that the router narrated in this user’s guide fits all basic demands of directive 1999/5/EC (R&TTE).