Service manual

58
Damper Motor Installation
When reinstalling the Damper Motor, align both Dampers to each other. If Dampers
are not in alignment the refrigeration may not properly function. Both motors must be
either open or closed as shown in (Fig. 11, 12). Also ensure the Damper are centered
in the damper box to prevent them from jams and causing misalignment. If the Damp-
er looks like (Fig. 13), it is incorrect and adjustments must be made it to correct it (Fig.
11, 12).
Fig. 12
Fig. 13
Open Position
Incorrect Alignment
Fig. 11
Closed Position
Correct Alignment