Final Safety Check
Once Service to oven is complete, but before applying power
to the oven, do the following: Use a Hipot Tester to ensure the wire
terminals are not loose or touching bare metal. Also ensure there
were no wires pinched or crushed during repair.
When Hipot testing the oven, it must be completely
assembled, with all covers and guards in their correct positions. The
recommended Hipot settings are listed below:
• Voltage – 1.25 (1250 volts)
• Current – 10.00 (10 mill amps)
• Dwell – 1.0 (1 second)
• Ramp/Pulse – 0.1 (1 second)
WARNING
If Oven passes Hipot test, proceed with functional test of oven. If
covers or guards are removed at any time, oven must be Hipot tested
once again to ensure safety, to you and the customer.
NOTE: Test each wire
individually. Connect Hipot
lead to White wire (Neutral),
connect another to chassis of
oven and test. If test passes,
then repeat test with the Red
(L2), and Black (L1) wire. See
(Fig. A).
Test 1
Test 2
Test 3
Conduit
Cable
Fig. A