User's Manual

Table Of Contents
Nonvolatile Parameter Database
AT+i Programmer‘s Manual Version 8.32 34-122
34.13.15 +iSWT SerialNET Wake-Up Timeout
Syntax: AT+iSWT=n Sets the SerialNET wake-up timeout when waking
up a remote SerialNET server.
Parameters: n = Number of seconds to allow the entire
SerialNET server wakeup procedure before
hanging up and retrying.
Command Options:
n = 0..65535 [seconds]
Default: 600 [seconds].
Result code:
I/OK If n is within limits.
I/ERROR Otherwise
AT+iSWT? Report the current SerialNET Wake-up timeout.
The reply is followed by I/OK.
AT+iSWT=? Returns the message ―0-65535‖.
The reply is followed by I/OK.