User's Manual

Connect One Electrical Specifications
6.3 AC Operating Characteristics
Figure
6-1: SPI Interface Waveforms
6.4 Tx Specifications
Item Condition Min Typ Max Unit
11b 15 dBm Transmit Power Levels
11g 15 dBm
Fc+/-11MHz 40 dBc 11b
Fc+/-22MHz 60 dBc
Fc+/-11MHz 30 dBc
Fc+/-20MHz 40 dBc
Transmit Spectrum Mask
11g
Fc+/-30MHz 50 dBc
Transmit Center Frequency
Tolerance
Temperature=25°C ±10 ppm
Table 4-3: Tx Specifications
6.5 Rx Specifications
Item Condition Min Typ Max Unit
802.11b Data Rate=11Mbps,
PER<8%
-88 dBm Receiver Minimum Input
Level Sensitivity
802.11g Data Rate=54Mbps,
PER<10%
-74 dBm
802.11b Data Rate=11Mbps,
PER<8%
48 dBc Adjacent Channel Rejection
Desired channel is 3dB above
sensitivity
802.11g Data Rate=54Mbps,
PER<10%
15 dBc
Table 4-4: Rx Specifications
PER(%)=(Number of all packets – Number of received packets)/(Number of all packetsX100)
WiReach BK Data Sheet 6-2