4.5.7.6  Traversing with a non-homed axis 
In the Axis > Homing dialog box, you specify whether the absolute positioning 
function is available at an axis which is not homed. 
Optional settings for "Homing required":  
•  No: Relative and absolute motions are possible. The software limit switches 
are monitored. 
•  Yes: relative motion only. The software limit switches are not monitored as long 
as the axis is not homed. 