Technical data
  Programming 
CPU 317T: Technology Functions 
A5E00251798-03 
5-9 
5.3  Monitoring busy commands 
All technology functions provide status outputs for monitoring current commands. 
As long as the input parameter Execute is set to TRUE, the status messages are 
retained (does not apply to the technology function MC_Stop). When you set a 
short Execute = TRUE signal, the status messages are output only in one 
execution cycle (see example 2 in the figure below). 
The Busy status bit indicates that the command is being executed, and that the 
output parameters of the technology function are being updated. 
Commands with defined termination 
The technology function provides an output parameter Done to signal the 
completion of commands of this type (example 1). Output parameter 
CommandAborted is set (example 3) if the execution of such a command is 
prematurely aborted. This may be triggered by the start of a further command at 
the same technology object, or by an error event. 