Technical data
  Technology functions 
CPU 317T: Technology Functions 
A5E00251798-03 
6-153 
MC_CamOutSuperImposed - ErrorIDs 
Valid for firmware version V3.1.x of the integrated technology 
ErrorID
Error message  Description / to correct or avoid error 
0000 No error  - 
8001  Internal fault  Faulty or inconsistent project / software. 
8005  Command canceled because of 
input buffer overflow 
The rate at which the user program outputs commands to 
the technology is too high. 
8007  An internal error has occurred at the 
job interface 
Due to an internal problem in the S7 system, commands 
can not be accepted. 
Check the consistency of your project data, then 
download all system data to the module again. 
8040  The axis / external encoder is not 
enabled, or the wrong mode is set 
The enable signal required for a motion command is 
missing. 
Eliminate and acknowledge all queued errors and then 
enable the axis in the relevant mode (e.g. position-
controlled). 
8043  Illegal parameter value 
Concerns the input parameters Mode or DoneFlag. 
This could also be a faulty configuration in S7T Config. 
8044  Task not supported by the 
technology object 
Send a command to a measuring sensor or cam. 
8045  Illegal command with current status  An MC_Stop command is busy, for example. 
804C  Command output rate too high  The command output rate with the same instance DB was 
higher than the command interface was able to accept. 
The second command is rejected in order not to violate 
consistency the first. 
For high command output rates, always use a separate 
instance DB, or send the command again. Please note, 
that although the first accepted command may be busy, 
you may not be able to monitor it at the status outputs. 
8050  Technology not ready  During testing with breakpoints (CPU in HOLD), the 
technology function has output a new command to the 
technology. The command is rejected. 