Technical data
  Technology DBs 
CPU 317T: Technology Functions 
A5E00251798-03 
7-7 
Variable Statusword.xxx 
The Statusword variable indicates the current status of the velocity-controlled axis. 
Bit
No.
Variable  Meaning of the status TRUE 
0  Statusword.DriveEnabled  Drive pulse enabled (not the axis!). At virtual axes, this value 
is always TRUE. 
Pulse enabled is not active in following mode ("MC_Power" 
with Mode = 3.) 
1  Statusword.HomingDone  Axis is homed, i.e. "MC_Home" was executed without error 
2  Statusword.Done  No motion command is being processed (MC_Power does 
not represent a motion command in this case). 
3  Statusword.SuperImposedCommand  A superimposing motion is active (e.g. 
"MC_MoveSuperImposed". 
4 Statusword.Error 
At least one error has occurred (ErrorID = 8xxx). 
Warning do not change the Error = FALSE status. 
5  Statusword.Errorstop  The axis is being stopped / was stopped due to an error; the 
technology object may be locked. 
Eliminate the cause and acknowledge the error. 
6  Statusword.Stopping  An MC_Stop command is busy at the axis. New motion 
commands are rejected. 
7  Statusword.Standstill  The axis velocity (absolute value) is lower than the set 
standstill limit. 
8  Statusword.PositioningCommand  A positioning command is active at the axis (may also be 
superimposing.) 
9  Statusword.SpeedCommand  A speed command is busy at the axis. Examples: 
•  MC_MoveVelocity 
•  "MC_MoveToEndPos" (before the fixed end stop is 
detected) 
10  Statusword.SynchrCommand  Irrelevant to the positioning axis. 
11  Statusword.Homing  The bit is set at the start, and reset at the end of MC_Home. 
12  Statusword.FollowUpControl  Remains set as long as following mode is enabled. 
This is not the case if the axis is shut down with "MC_Power" 
or switched on with Mode = 3. 
13  Statusword.ConstantVelocity  Is set as long as the velocity setpoint remains constant. 
14  Statusword.Accelerating  Axis is accelerating (increasing drive power). 
15  Statusword.Decelerating  Axis is decelerating (declining drive power). 
16  Statusword.RequestRestart  Axis parameters were changed and do not take effect until 
after the next restart (MC_Reset with Restart = TRUE). 
17  Statusword.Simulation  Axis in simulation mode. 
You achieve this with MC_Power by setting Mode = 4. 
18  Statusword.CyclicInterface  Cyclic communication between the integrated technology 
and the drive is active. 
At a virtual axis. this value is always TRUE. 
19  Statusword.EncoderValid  The actual position of the encoder that is relevant to the axis 
is valid (of particular importance in the startup phase of 
absolute value encoders). 
20  Statusword.SpeedMode  The axis motion is velocity-controlled by "MC_MoveVelocity" 
(PositionControl = FALSE). 










