Technical data
Appendix 
  CPU 317T: Technology Functions 
A-36  A5E00251798-03 
No. Name 
(standard in S7T Config) 
Name 
(Expert list in S7T Config) 
Data type  Index  min.  max.  Access 
Active  D P V Description 
1274 Monitoring Synchronous 
operation monitoring Activation 
of setpoint monitoring 
TypeOfAxis. 
GearingPosTolerance. 
enableCommandValue 
DINT Enum 
Gearing 
PosTolerance 
Command 
Value 
 -   -   -  R, W  Immediately      X  Setpoint tolerance monitoring
1275 Monitoring Synchronous 
operation monitoring Message 
to master 
TypeOfAxis. 
GearingPosTolerance. 
enableErrorReporting 
DINT Enum 
ErrorReporting 
 -   -   -  R, W  Immediately      X  Message of tolerance 
monitoring 
1281  Limits Position and Speed 
Hardware limit switches 
Activation 
TypeOfAxis. HWEndPos. 
Enable 
DINT 
EnumYesNo 
 -   -   -  R, W  Restart  X  X  X  Activation of limit switches 
1284  Position and speed limits 
Hardware limit switch.Modus 
TypeOfAxis.HWEndPos. 
Mode 
DINT 
EnumMount 
Switch 
 -   -    R, W  Restart  X  X  X  Position of the HW limit 
switch relative to the axis 
traversing range 
1291  Limits Dynamic response 
Acceleration Activation of 
monitoring functions 
TypeOfAxis.MaxAcceleration. 
enableSetPointMonitoring 
EnumYesNo   -   -   -  R, W  Restart  X  X  X  Enable manipulated variable 
monitoring 