Technical data
Basic functions   
4.2 Homing 
  Connection of the SINAMICS S120 to the Technology CPU 
112  Product Information, 09/2011, A5E00480378-04 
Inverting the selected digital input of the SINAMICS 
A general condition in conjunction with SINAMICS governs the homing only with an external 
zero mark. Only negative edges are permitted for the positive travel direction and only 
positive edges are permitted for the negative travel direction, this means that the same cam 
side is always used. This means that your construction circumstances may require that the 
BERO signal needs to be inverted. 
To invert the Bero signal, switch in the S7T Config project navigator to the dialog box: 
"\Technology\SINAMICS_S120\Control_Unit. Mark the "Control_Unit" entry and select 
Expert list in the shortcut menu in order to open the expert list. Parameter "p490.9 DI/DO 9 
(X122.8)" allows you to invert the digital input DI/DO 9. 
A separate parameter is provided for inverting each digital input that can be used to fetch the 
external zero mark. The following table contains the correct parameters for the selected 
digital input: 
P490.9  DI/DO 9  X122.8 
P490.10  DI/DO 10  X122.10 
P490.11  DI/DO 11  X122.11 
P490.13  DI/DO 13  X132.8 
P490.14  DI/DO 14  X132.10 
P490.15  DI/DO 15  X132.11 
This completes the assignment of the internal digital input of the CU320 to the equivalent 
zero mark signal in the SINAMICS. 