Technical data
Expert Functions   
5.6 Measuring Function 
  Connection of the SINAMICS S120 to the Technology CPU 
164  Product Information, 09/2011, A5E00480378-04 
Creating and configuring measuring inputs in S7T Config 
To create and configure a measuring input, follow these steps: 
1. Switch to the Technology > Axes > Axis_1 > Measuring input folder in the 
S7T Config project navigator. 
2. Insert the measuring input in the project by clicking "Insert measuring input". 
A dialog opens. 
3. Click "OK" to confirm the unchanged settings. 
4. To parameterize the measuring input, switch to the 
Technology > Axes > Axis_1 > Measuring inputs > Measuring input_1 > Configuration 
dialog in the S7T Config project navigator. 
The "Configuration" dialog opens. 
5. Enter the following input address for this example: PI 323.0. 
The address 323 is derived from the offset address of TM17 of 3 bytes and from the 
PROFIBUS address of the TM17 module of 320 bytes. 
The bit address results from the use of the first DI/O 0 input on the 
TM17 terminal module. 
Result 
This completes the configuring in S7T Config. 
As the next step, you will have to create the user program. 