Technical data
Safety Integrated Functions in 
SINAMICS Drive Systems   
6.7 Control via PROFIsafe 
  Connection of the SINAMICS S120 to the Technology CPU 
204  Product Information, 09/2011, A5E00480378-04 
Structure of PROFIsafe control word (S_STW1, PCD1 in message frame 30, output signals) 
Table 6- 5  Structure of the PROFIsafe control word 
Bit  Meaning  Remarks  BICO 
1  STO deactivation 0  STO 
0  STO activation 
r9720.0 
1  SS1 deactivation 1  SS1 
0  SS1 activation 
r9720.1 
1  SS2 deactivation 2  SS2 
0  SS2 activation 
r9720.2 
1  SOS deactivation 3  SOS 
0  SOS activation 
r9720.3 
1  SLS deactivation 4  SLS 
0  SLS activation 
r9720.4 
5  Reserved  -  -  - 
6  Reserved  -  -  - 
1/0  Acknowledgment 7  Internal Event ACK 
0  No acknowledgment* 
r9720.7 
-  - 8  Reserved 
-  - 
- 
9  Select SLS bit 0  -  r9720.9 
10  Select SLS bit 1  - 
Selection of the speed limit for SLS 
(2 bits) 
r9720.10 
11...15  Reserved  -  -  - 
* Acknowledgment takes place via positive edge change. 