Technical data
  Safety Integrated Functions in 
SINAMICS Drive Systems 
  6.7 Control via PROFIsafe 
Connection of the SINAMICS S120 to the Technology CPU 
Product Information, 09/2011, A5E00480378-04 
205 
Structure of PROFIsafe status word (S_ZSW1, PCD1 in message frame 30, input signals) 
Table 6- 6  Structure of the PROFIsafe status word 
Bit  Meaning  Remarks  BICO 
1  STO active 0  STO active 
0  STO deactivated 
r9722.0 
1  SS1 active 1  SS1 active 
0  SS1 deactivated 
r9722.1 
1  SS2 active 2  SS2 active 
0  SS2 deactivated 
r9722.2 
1  SOS active 3  SOS active 
0  SOS deactivated 
r9722.3 
1  SLS active 4  SLS active 
0  SLS deactivated 
r9722.4 
5  Reserved  -  -  - 
6  Reserved  -  -  - 
1  Internal event 7  Internal Event 
0  No internal event 
r9722.7 
inverted 
-  - 8  Reserved 
-  - 
- 
9  Active SLS level bit 0  -  r9722.9 
10  Active SLS level bit 1  - 
Display of the velocity limit for SLS 
(2 bits) 
r9722.10 
1  SOS selected 11  SOS selected 
0  SOS deactivated 
r9722.11 
12...14  Reserved  -  -  - 
1  SSM (speed below limit value) 15  SSM (speed) 
0  SSM (speed higher than/equal to limit) 
r9722.15 