Technical data
Commissioning   
3.4 Configuring the drive components 
  Connection of the SINAMICS S120 to the Technology CPU 
56  Product Information, 09/2011, A5E00480378-04 
Configuring with Smart Line Module (SLM) 
1. In S7T Config, open the SINAMICS S120_CU320 folder, and double-click the 
"Configure drive unit" entry or the drive. 
2. Insert the control unit and optionally the add-on modules, for example TB30 terminal 
board. Select the desired values and click "Next" to confirm the settings. 
3. For the selection of the SINAMICS infeed, you can choose between modules with or 
without DRIVE-CLiQ connection. Select the appropriate setting and click "Next" to confirm 
the setting. The following steps are for Smart Line Modules without DRIVE-CLiQ. 
For modules with DRIVE-CLiQ infeed, proceed as for the configuration with Active Line 
Modules (ALM). 