Technical data
Commissioning   
3.7 Diagnosing the technology configuration 
  Connection of the SINAMICS S120 to the Technology CPU 
88  Product Information, 09/2011, A5E00480378-04 
Enabling the infeed for a Smart Line Module 
The ready signal is used to enable a Smart Line Module without DRIVE-CLiQ interface. 
As shown in the chapter "Manual configuring" (Page 39), Configuration with 
Smart Line Modules (SLM
)", this was connected when you configured the 
Smart Line Module. Ensure that the ready signal has logical value 1 in order to enable the 
Smart Line Module. 
Enabling the axis using the axis control panel 
To do this, open the axis control panel in S7T Config using "Technology\Axes\Axis_1\Control 
panel" and select the required axis from the dropdown list box. Transfer the control priority to 
the axis control panel by clicking the "Assume control priority" button and acknowledging the 
message that appears by clicking the "Accept" button. 