Technical data
Basic functions   
4.1 Encoder settings 
  Connection of the SINAMICS S120 to the Technology CPU 
94  Product Information, 09/2011, A5E00480378-04 
Cyclical actual value: Gn_XIST_1 
In the "cyclical actual value" Gn_XIST_1 (n = 1 or 2, number of the encoder), the incremental 
change in position of the encoder is transmitted to the PLC. The drive simply evaluates the 
counting pulses of the encoder, and generates the "cyclical actual value" from them. 
As soon as the drive control unit is connected to the supply voltage, the value zero is always 
transmitted via the "cyclical actual value". 
The "cyclical actual value" Gn_XIST_1 is always filled by the drive unit, irrespective of 
whether an absolute encoder or an incremental encoder is being used. 
Note 
The data bits of the "cyclical actual value" Gn_XIST_1 (n = 1 or 2, number of the encoder) 
must correspond to the structure of the encoder actual value that is configured in 
S7T Config. Otherwise, the position information transferred from the encoder to the PLC 
will be incorrectly interpreted by the technology CPU. 
Absolute actual value: Gn_XIST_2 
Non-cyclical encoder values are transmitted in the "absolute actual value" Gn_XIST_2 
(n = ...). These values must be requested by the PLC prior to transmission. 
The following values may be requested by the PLC via the axis message frame: 
●  Absolute value of the encoder if an absolute encoder is being used. 
●  Synchronization position when a synchronization mark (e.g. reference mark) is overshot, 
and requested synchronization function (e.g. on-the-fly homing). 
●  Measurement position when a measuring input on the drive is triggered, 
and a measurement function is requested. 
The "absolute actual value" is not described with valid values which can then be evaluated in 
the PLC until the drive has executed the requested function. 