User manual
3-38  Chapter 3: Software Installation - Windows NT 
Echo User's Manual, ver. 0.00 
Figure 16: Windows NT: switch settings 
When ON
,
p
ort 1 is COM1 
(
3F8 hex
)
When ON, port 2 is COM2 (2F8 hex) 
Reserved - must be OFF 
Base address sets: 
Port 1 = address 280 hex 
Port 2 = address 288 hex 
Status port address 
When OFF, status port is disabled
IRQ channel(s) 
All ports will interrupt on Channel A
SW1
Port 3 = address 290 hex 
Port 4 = address 298 hex 
Port 5 = address 2A0 hex 
Port 6 = address 2A8 hex 
Port 7 = address 2B0 hex 
Port 8 = address 2B8 hex 
2.  Choose an IRQ for your Echo. It is possible to have the even 
ports on one IRQ and the odd ports on a different IRQ, but 
we recommend having all ports on one IRQ. Good choices of 
IRQ's are 5, 10, 11, 12 and 15. The two serial ports that 
come with your system usually use IRQ 4, 3 and LPT1 is 
usually IRQ 7. Please refer to the Table showing typical IRQ 
usage in Chapter 2: Hardware Installation. For our 
example we will choose IRQ 10. Figure 17 shows the 
example IRQ setting. Please refer to Figures 2, or 3 in 
Chapter 1: Introduction for the location of the jumper block 
J1. 