Specifications
Page 12
Computer Connection:
To open the RS-232 port for computer program-
ming, set all four Range switches OFF and RESET
POWER. The port is now open for serial communi-
cation with any IBM compatible personal computer
loaded with Coiltek CSWIN32 Control Software.
The CSWIN32 Software can be downloaded from
our website. www.coiltek.com
NOTE. Unless a computer is connected, at least one range switch should remain ON to
close the port and protect the unit from noise.
WARNING! All four switches can be ON at the same time to create a 75-inch range pro-
vided the TEST switch (on SW2) is OFF. Applying power with all four Range switches and
the TEST switch ON will erase the active program and substitute factory default settings
into memory. Look under TROUBLESHOOTING on Page 14.
SW 2
Offset #1, #2, #3: Some drive systems do not react until the control voltage reaches a certain
value. (This problem often shows up in payout applications.) These switches
introduce offset bias — equivalent to a minimum speed setting. When the
control signals the drive to start, its output voltage jumps from 0 to a preset
percentage of the maximum signal output voltage (set by the Output Level
Adjust). Figure 1 (Page 8) gives the offset value settings.
PreSet #1, #2, #3 CS-5000 Series controls store up to seven operating programs. Figure 1
(Page 8) shows switch settings associated with the programs. Any setting
other than 0, lets the stored program superceed all other switch settings. You
can transfer programs manually-set parameters from Program 0 into preset
locations, or use Coiltek CSWIN32 computer software to store parameters
for each program.
TEST: This switch is used to reset default parameters (See RANGE SWITCHES)
and for factory tests and servicing. With TEST switch ON and at least one
(BUT NOT ALL) Range switches ON, the control runs a self-test. SWITCH
OUTPUTS (CONTROL, NEAR, & FAR) turn ON and OFF in sequence.
Master — Slave: Normal setting is OFF: Master. When multiple controls are connected for
multiplexed operation, set this switch is in Slave position on all units. See
Figure 3 (Page 16).
0% Offset
5.7% Offset
13.5% Offset
0%
50%
100%
Distance from Sensor
Output Voltage
Control Range
PAYOUT MODE
0%
50%
100%
Output Voltage
Control Range
Distance from Sensor
TAKEUP MODE