Additional data link
A data link requires an unused circuit card. If necessary, install and connect a new circuit card.
The table below shows the circuit cards that can be used to connect data terminals and set up
data links.:
Connecting the data link
Configure the card as specified in Appendix A.
Declaring the data link
To make the link operational, it must be assigned an extension number, then put in service.
To ensure that the ICS recognises the new terminal/data link:
1 Go to menu 2.1.1 (Link characteristics). The screen
LINK SELECTION appears.
2 On the line
BY EQUIPMENT NUMBER, enter the equipment number of the circuit card.
3 The system recognises the card installed (CA1 or CS1) and asks for the link type to be
specified.
4 On the line
TYPE OF LINK, select the link type. Press Enter.
5 The screen
LINK CHARACTERISTICS appears. Change any characteristics required, to
customise the link.
6 On the line
STATUS, select IN SERVICE. Press Enter. The line IN SERVICE is displayed.
The connected data link or terminal becomes operational as soon as its status switches to "in
service".
Circuit card Data interface
CA1 4 asynchronous V24 interfaces
CS1 2 asynchronous X25 interfaces
Circuit card TYPE Terminal
CA1 (asynchronous V24) PAD
VIDEOPAD
EBVO
PC
M1B-CONNECTED
M1B LOCAL
SPTEL
MINITEL CONNEC
MINITEL LOCAL
TTY
VT100
TVI-955
WYSE -65
CS1 (synchronous X25) PSDN
HDLC LOCAL
INTER NETWORK.