Installation manual

PS10270JENAA01 20/10/2004 133
Errors detected in a file
These errors are generated by programs that handle files located in hard disk RAM
directories:
*ERR 020D*PCS 0*LC 50454*PCD 000*IND 01
02 0E 02 00 00 00 00 00 35 72 ...
30 32 35 36 41 42 30 36 30 32 ...
..../UTD/DATA/ML/VQ50256AAB0602
The fault record recorded in the logbook contains:
Hardware error
This type of error message is generated when an event is detected on a card, card
component, or any other hardware part monitored by the software. A hardware device is any
device that has a software manager.
***ERR0R:0604
*******LA6: 0, 0, ..
The fault record associated with a hardware device and recorded in the logbook contains:
Fail safe action report
When an error is detected, automatic maintenance can take fail safe action. The action consists in
changing the status of the security block that encompasses the faulty hardware device and
generating a report:
******LA6 :0, 0, .. ** FAULTY **
The fail safe action report recorded in the logbook contains:
the type of security block that changed status
the security block number
the new logical security block status
ERR
Error number. See Appendix C for the meaning of each number.
PCS
Processor number. 0 indicates the OCX card.
LC
Identification number of the program that detected the fault.
PCD
Software procedure number.
IND
Index used to identify the location of an instruction in the program.
Any additional fault-related information, displayed in a byte string, is listed after the Index code.
ERROR
Error number of the fault. See Appendix C for the meaning of each number.
*******LA6
Type of hardware device.
HARDWARE DEVICE
NUMBER
Number of faulty hardware device.
Any additional fault-related information, displayed in a byte string, is listed after the hardware device number.