Installation manual

PS10270JENAA01 20/10/2004 183
Description of the connectors
Description of the switches
There are no switches on this card.
Description of lights
There are no lights on this card.
Line characteristics
Line resistance, including set: 500 Ohms
0.4 mm cable: approximately 2 km (maximum distance between set and cabinet)
0.6 mm cable: approximately 3.5 km (maximum distance between set and cabinet)
The voltage and current measured at the set terminals during a conversation must be:
U = 12.4 V / I = 25 mA
All the analogue sets connected to the ICS must be have the following settings:
Z impedance ref. 2 (complex impedance)
self-regulating
NAME Function Description of the contacts
J2 connector for connecting two
analogue sets
pins 4 and 3: analogue set 0
pins 2 and 1: analogue set 1
J3 connector for connecting two
analogue sets
pins 4 and 3: analogue set 2
pins 2 and 1: analogue set 3
1
4
1
4