Description of the switches
CA1.1 to CA1.4 : these switches are used to adapt lines (factory setting, leave set to ON).
CA2: configure according to the card's location and mode (master/slave).
Case of LD4 in T0 configuration (shelf 0 of the main cabinet only)
SW1: factory reserved; leave in position 1-2.
SW3, SW4, SW5, and SW6: these jumper switches are used to disable each interface's remote
power supply when a T0 interface is connected.
SW7 and SW8: these jumper switches are used to set either a 40 V or 48 V remote power supply
Description of lights
CA2.1
(VALH)
Function
ON CA2.1 is active only in Shelf 0 in the main cabinet (positions 0-5).
Set it to ON if the LD4 card is used in T0 mode, to synchronise the PBX clock
with the public network clock.
OFF Set to OFF:
- if the LD4 and LD4N cards used in T0 or LT2 are in positions 2 and 4
because they cannot simultaneously transmit the clock ("or" cabled),
- if the LD4 and LD4N cards used in T0 or LT2 are in positions 3 and 5 (the
PBX has only four clock inputs). These positions 3 and 5 correspond to the
priority clock input of the OCT3B or OCT4 CPU.
Case of LD4 in S0 configuration (for DECT BS)
CA2.2 (M/S) Function
M LD4 master: position not allowed with an OCT4 card
S to be set in position E on all LD4 cards
SW3
Remote power supply for interface 3
SW4
Remote power supply for interface 2
SW5
Remote power supply for interface 1
SW6
Remote power supply for interface 0
SW7 and
SW8
Positions Function
1-2 Selects the 48 V power supply
2-3 Selects the 40 V power supply
NAME Color Function