Installation manual
202 20/10/2004 PS10270JENAA01
Description of the connectors
Description of the switches
There are no switches on this card.
Description of lights
There are no lights on this card.
Line characteristics
Analogue sets
Line resistance, including set: 500 Ohms
• 0.4 mm cable: approximately 2 km (maximum distance between set and cabinet)
• 0.6 mm cable: approximately 3.5 km (maximum distance between set and cabinet)
The voltage and current measured at the set terminals must be:
• U = 12.4 V / I = 25 mA
All the analogue sets connected to the PBX must be have the following settings:
• Z impedance ref. 2 (complex impedance)
• self-regulating
Digital sets
• 0.4 mm cable: approximately 1 km (maximum distance between set and cabinet)
• 0.6 mm cable: approximately 1.8 km (maximum distance between set and cabinet)
The voltage and current measured at the set terminals must be:
• U = 12.4 V / I = 25 mA
All digital sets are protected against most problems caused by human error: short-circuiting,
connection to an analogue extension socket, etc. In such cases, the set will remain silent.
NAME Function Description of the contacts
J2 used to connect two analogue sets pins 4 and 3: analogue set 0
pins 2 and 1: analogue set 1
J3 used to connect two analogue sets pins 4 and 3: analogue set 2
pins 2 and 1: analogue set 3
J4 used to connect two digital sets pins 4 and 3: digital set 0
pins 2 and 1: digital set 1
J5 used to connect two digital sets pins 4 and 3: digital set 2
pins 2 and 1: digital set 3
1
4
1
4
1
4
1
4