Installation manual
206 20/10/2004 PS10270JENAA01
Description of the connectors
Line characteristics
• 0.4 mm cable: approximately 1 km (maximum distance between set and cabinet)
• 0.6 mm cable: approximately 1.8 km (maximum distance between set and cabinet)
The voltage and current measured at the set terminals must be:
• U = 12.4 V / I = 25 mA
All digital sets are protected against most problems caused by human error: short-circuiting,
connection to an analogue extension socket, etc. In such cases, the set will remain silent.
NAME Function Description of the contacts
J2  used to connect two digital sets pins 4 and 3: digital set 0
pins 2 and 1: digital set 1
J3 used to connect two digital sets pins 4 and 3: digital set 2
pins 2 and 1: digital set 3
J4 used to connect two digital sets pins 4 and 3: digital set 4
pins 2 and 1: digital set 5
J5 used to connect two digital sets pins 4 and 3: digital set 6
pins 2 and 1: digital set 7