Installation manual

PS10270JENAA01 20/10/2004 235
214 A programming error was detected by the IRMX286 monitor.
If the IRMX error code is different from C008H/C00AH/C00CH:
- error code IRMX286 (appendix 3): 1 word.
- DS, ES, DI, SI, BP, SP, BX, DX, CX, AX: 14 words.
fault code, IP, CS, flags
- first words in stack.
If the IRMX error code is C008H/C00AH/C00CH:
- error code IRMX286: 1 word.
- processor error code: 1 word.
- IP, flags: 2 words.
- AX, CX, DX, BX, SP, BP, DI: 8 words.
- ES, CS, SS, DS: 4 words.
- first words in stack (SS:SP).
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
601 The OCX card does not recognise an address.
Program registers interrupted:
- register NMI, BP, DS, ES, DI, SI, BP, SP.
- BX, DX, CX, AX, IP, CS, Flags.
- first words in stack.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
602 Software watchdog has been triggered by the CPU software loop or interrupt.
Program registers interrupted:
- register NMI, BP, DS, ES, DI, SI, BP, SP.
- BX, DX, CX, AX, IP, CS, Flags.
- first words in stack.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
603 - Incorrect data has been transmitted by the system bus.
Program registers interrupted:
REB, BP, DS, ES, DI, SI, BP, SP.
BX, DX, CX, AX, IP, CS, Flags.
first words in stack.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
604 An incorrect I/0 card access instruction was given.
Action
Contact the maintenance support team. The state of the card is changed to faulty.
606 An overall power supply problem has occured.
Action
Monitor the error. The system automatically restarts when this error occurs.
Error
number
Description
- Folio 3 de 8 -