Installation manual
236 20/10/2004 PS10270JENAA01
607 The processor has shut down.
Program registers interrupted:
- REB, IP, CS, flags
- DS, ES, DI, SI, BP, SP, DX, CX, AX.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
608 The OCT card does not recognise the I/O address.
Program registers interrupted:
- REB, BP, DS, ES, DI, SI, BP, SP.
- BX, DX, CX, AX, IP, CS, Flags.
- first words in stack.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts when this error occurs.
700 The CLX card cannot be woken up.
Action
Monitor the error. The state of the card is changed to faulty.
701 Fatal CLX card error while loading.
- the first two bytes in the IRRD area.
- the first indicates the erroneous phase number. The second is the general error report.
Action
Monitor the error. The state of the card is changed to faulty.
702 There is no initialisation report from the CLX card software.
Action
Monitor the error. The state of the card is changed to faulty.
703 The CLX card does not recognise an address.
- program register interrupted:
- CS, IP, flags.
- DS, RS, DI, SI, DX, CX, AX, BP, SP.
*1 register is displayed as 2 inverted bytes.
Action
Monitor the error. The system automatically restarts the CLX card when this error occurs.
705 CLX card has a software loop or shutdown.
Action
Monitor the error. The system automatically restarts the CLX card when this error occurs.
706 A spurious NMI has occurred on the CLX card.
Action
Monitor the error. The system automatically restarts the CLX card when this error occurs.
707 Too frequent CLX card automatic restarts.
Statistics counter value.
Action
Monitor the error. The system automatically changes the CLX card status to faulty when this
error occurs. Contact the maintenance support team.
Error
number
Description
- Folio 4 de 8 -