Installation manual

238 20/10/2004 PS10270JENAA01
3E00 Unsuccessful call due to establishment failure on level 2.
2 specific program words.
*1 word is displayed as 2 inverted bytes.
Action
Monitor the error.
3E01 There is an activation problem on T0 access.
2 specific program words.
*1 word is displayed as 2 inverted bytes.
Action
Monitor the error.
4800 The LB4 card cannot be woken up.
Card number.
Action
Monitor the error. The state of the card is changed to faulty.
4801 A fatal LB4 error occurred while loading (start-up test report = failure)..
The first bytes in the OCX-LB4 communication area. The first byte indicates the number of
erroneous tests, the second gives the number of the first erroneous test (bits 0-3 = phase, .
bits 4-6 = no test).
Action
Monitor the error. The state of the card is changed to faulty.
4802 The end of initialisation message was not received from LB4 card software.
Action
Monitor the error. The state of the card is changed to faulty.
4803 The LB4 card does not recognise an address.
Program registers interrupted:
- CS, IP, Flags
- DS, ES, DI, SI, CX, AX, BP, SP.
*1 register is displayed as 2 inverted bytes.
Action
aucune action, information pour l’opérateur.
4805 The resident LB4 card software has a software loop or interrupt.
Monitor the error. The system automatically restarts the LB4 card when this error occurs.
4806 A spurious NMI has occurred on the LB4 card.
Monitor the error. The system automatically restarts the LB4 card subsequent to this error.
4807 The LB4 card has automatically restarted too frequently.
Statistics counter value.
Monitor the error. The system automatically reacts to this error on the LAC card.
4808 The LB4 card is mute.
Action
Monitor the error. The system automatically restarts the LB4 card when this error occurs.
4900 The BS card cannot be loaded on the LB4 card.
Action
Monitor the error. The system automatically changes the base station status to faulty when this
error occurs.
Error
number
Description
- Folio 6 de 8 -