Installation manual
240 20/10/2004 PS10270JENAA01
6F03 The type of 2-channel BS coding when this error occurs is not compatible with that of the PBX.
Action
Monitor the error. The system automatically changes the base station state to faulty when this 
error occurs.
7004 Onset of PCM alarm on an LT2_RTC card.
- frame alarm register (8 least significant bits): 1 word.
- multiframe alarm register (8 least significant bits): 1 word.
1 word is displayed as 2 inverted bytes.
Action
No action, information for the administrator
7005 The alarm on the PCM of the LT2_RTC card ends.
- multiframe alarm register (8 least significant bits): 1 word.
1 word is displayed as 2 inverted bytes.
Action
No action, information for the administrator
7006 Alarm of a PCM blocked junctor on LT2_RTC card
Action
No action, information for the administrator
7007 Alarm of a PCM blocked junctor on LT2_RTC card ends
Action
No action, information for the administrator.
Error 
number
Description
- Folio 8 de 8 -